Testing Machine Load Cell ( RSL 203 )

testing machine load cell

Data Sheet

The testing machine requires smart scale with the ability to calculate the parameters accurately. And in this regard, testing machine Load Cell is another suitable appliance that is manufactured with the latest and advanced technology. The model name of this machine is RSL 203. It is easy enough to install and suitable for work in multiform environmental condition.

The collection of testing machine load cell is configured with the tough body. Moreover, it is packed with a user-friendly design. The products are manufactured with quality product material to ensure the final quality of this product before final supply to the customers.

Wiring Schematic Diagram:

Dimenstions:

CAP D D1 d M H H1
200kg to 5000kg 105 90 6.2*8 M16*1.5 32 36
10000kg&15000kg 115 90 10.2*8 M30*2 40 42
20T to 30T 155 125 16.5*8 M39*2 50 52
50T 205 165 16.5*8 M48*2 60 65
100T 280 222 20.5*8 M72*2 90 95
Features:
  • Alloy steel & Stainless steel structure
  • Nickel plated
  • Suitable for multiform environments
  • Easy to Install & Use
Applications:
  • Electronic Truck Scales
  • Truck Scales, Hooper Scales
  • Other Electronic Weighing Devices
Parameters:
Related Load (Ton) 0.2, 0.5, 1, 2, 3, 5, 10, 20, 30, 50, 100
Precision C2 Insulation Resistance(MΩ)≥5000(100VDC)
Composition Error 0.03 Excitation Voltage (V)9~12 (DC)
Rated Output (mv/v)2 0.008 Compensated temp. Range (C)-10~+40
Non-Linearity (%FS)0.017 Use Temp. Range (C)-20~+55
Hysteresis (%FS)0.02 Temp. Effect on Zero (%FS/10C)0.05
Repeatability (%FS)0.01 Temp. Effect on Span (%FS/10C)0.03
Creep (%FS/30min)0.03 Safe Overload (%FS)150
Zero Balance (%FS) 1 Ultimate Overload (%FS)200
Input Resistance (Ω)750 10 Defend GradeIP66
Output Resistance (Ω)700 5 Cable6mm, 10mtr